+ | ===== Reading Inverters via Ethernet ===== | ||
+ | |||
+ | |||
+ | ---- | ||
+ | |||
+ | |||
+ | <WRAP half column> | ||
+ | \\ | ||
+ | \\ | ||
+ | \\ | ||
+ | To be set up in the submenu Inverters and Measuring </ | ||
+ | </ | ||
+ | <WRAP half column> | ||
+ | \\ | ||
+ | Select the manufacturer of your inverter. </ | ||
+ | \\ | ||
+ | <WRAP info> Setting up network interface has two address modes: | ||
+ | 1. IP Address\\ | ||
+ | 2. Port\\ | ||
+ | </ | ||
+ | ==== IP Address Detection of Inverters ==== | ||
+ | |||
+ | |||
+ | Use this type of detection for inverters with different IP addresses.\\ | ||
+ | \\ | ||
+ | <WRAP info> Address the inverters first. Assign consequent IP addresses to the inverters and the port number. The port number is the same for all inverters. Further info on how to address the inverters to be found in inverter' | ||
+ | \\ | ||
+ | **IP Address** \\ | ||
+ | Enter inverter with the lowest IP address in the network. Detection starts with this address and searches for following higher IP addresses until the required number of destinations has been searched.\\ | ||
+ | \\ | ||
+ | {{ : | ||
+ | Enter port's number.\\ | ||
+ | \\ | ||
+ | <WRAP half column> </ | ||
+ | Select addressing mode depending on the IP address.\\ | ||
+ | \\ | ||
+ | **The number of destinations** \\ | ||
+ | The number of IP addresses of all devices.\\ | ||
+ | \\ | ||
+ | **Detected devices** \\ | ||
+ | The number of devices assigned to each destination.\\ | ||
+ | \\ | ||
+ | **Read Connected Inverters** \\ | ||
+ | Click on button{{: | ||
+ | \\ | ||
+ | Detection can take up to several minutes depending on the type of protocol and the number of inverters. <WRAP info> To be detected, inverters must be on, i.e. they must have sufficient electric current coming from the PV panels. </ | ||
+ | \\ | ||
+ | \\ | ||
+ | \\ | ||
+ | \\ | ||
+ | Save changes you have made{{: | ||
+ | \\ | ||
+ | </ | ||
+ | \\ | ||
+ | ==== Port Detection of Inverters ==== | ||
+ | |||
+ | |||
+ | Use this type of detection for inverters with the same IP address that are located at different ports.\\ | ||
+ | \\ | ||
+ | <WRAP info> Address the inverters first. Assign one IP address for all inverters. Assign consequent numbers of ports to inverters. Addressing procedure to be found in inverter' | ||
+ | \\ | ||
+ | **IP address** \\ | ||
+ | Enter IP address, the same address for all inverters.\\ | ||
+ | \\ | ||
+ | {{ : | ||
+ | Enter inverter with the lowest port number (destination) at a particular IP address. Detection starts with this port and searches for following higher port numbers until the required number of destinations has been searched.\\ | ||
+ | \\ | ||
+ | <WRAP half column> </ | ||
+ | Select addressing mode according to the port.\\ | ||
+ | \\ | ||
+ | **The Number of Destinations** \\ | ||
+ | The number of ports where the devices have been addressed.\\ | ||
+ | \\ | ||
+ | **Detected devices** \\ | ||
+ | The number of devices assigned to each destination.\\ | ||
+ | \\ | ||
+ | \\ | ||
+ | Read connected inverters**\\ | ||
+ | Click on button{{: | ||
+ | \\ | ||
+ | Detection can take up to several minutes depending on the type of protocol and the number of inverters. <WRAP info> To be detected, inverters must be on, i.e. they must have sufficient electric current coming from the PV panels. </ | ||
+ | \\ | ||
+ | \\ | ||
+ | \\ | ||
+ | \\ | ||
+ | Save the changes you have made {{: | ||
+ | \\ | ||
+ | </ | ||