+ | ===== Parametry základního modulu ===== | ||
+ | |||
+ | ---- | ||
+ | |||
+ | |||
+ | {{ : | ||
+ | |||
+ | |||
+ | ^Max. number of devices< | ||
+ | |SM2-MU Basic and SM2-MU Start | 1 device< | ||
+ | | SM2-MU 60 | 6 devices< | ||
+ | | SM2-MU 300 | 30 devices< | ||
+ | | SM2-MU 1000 | 100 devices< | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Supported devices< | ||
+ | | Communication | Ethernet (TCP), up to 3 serial ports | | ||
+ | | Inverter protocols | AEG, Carlo Gavazzi, Danfoss, Delta, Diehl, Fronius, IBC Solar, Kaco, Kostal, Mastervolt, Morningstar, | ||
+ | | Meter protocols | ABB (REX521), Carlo Gavazzi (VMU-E/X), Fronius (Smart Meter), KMB (SMC-144, PA-144), Phoenix Contact (MA200/ | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Sensors ^ Dallas 1-wire bus | | ||
+ | | Interface | Screw terminals for 05 mm² - 15 mm² cores | | ||
+ | |Max. count | 10 sensors | | ||
+ | |Max. distance | 100 m, recommended max. cable length for daisy‑chained sensors with minimal trunk segments | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Ethernet interface (LAN) ^ | | ||
+ | |Interface | RJ45 (100BASE-T) -100Mbit/s, compatible with networks 10/100/1000 Mbit/s, auto MDIX | | ||
+ | | Protocols | HTTP, SOAP, DNS, UDP Setup, Telnet, ARP, ICMP, SMTP, SNMP, Modbus | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^RS485 / RS422 / RS232 ^ | | ||
+ | |Interfaces | 2x RS485 or 1x RS422< | ||
+ | | | | | ||
+ | | | __// | ||
+ | | | 2x RS485 or 1x RS422 opto-isolated< | ||
+ | | | 1x RS485 + 1x RS232 | | ||
+ | | | 1x RS485 + 1x RS232 opto-isolated | | ||
+ | | | | | ||
+ | | | //__SM2-BE extension module__ // | | ||
+ | | | 1x RS232 + 1x RS485 surge protected< | ||
+ | | | | | ||
+ | |Speed | 300 .. 115.200 bps (software configurable)< | ||
+ | |Termination | Yes, both for half and full duplex, configurable with jumpers | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Inputs ^ opto-electronically isolated | | ||
+ | | 3x digital inputs (DI) | software configurable between dry contact or S0 pulse meter inputs (e.g. from electrometer) | | ||
+ | | Max. distance | 30 m (depends on cable) | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Outputs ^ | | ||
+ | |1x relay | 32 V, 3 A, protected with power fuse | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Electrical parameters ^ | | ||
+ | |Power supply | 9-35 V DC, typ. 1.2 W @ 12V | | ||
+ | | DI1, DI2, DI3 | 8-80 V | | ||
+ | | 1 Wire | Interface provides 5 V power supply, max. 350 mA, protected with 500 mA power fuse. | | ||
+ | | RS485 | Protected against transient voltages above 6.8V and against high currents with 10Ω resistors. Additional surge protection can be achieved with SM2-BE (bus extension) module with gas discharge tubes: | | ||
+ | | | Minimum DC Sparkover (100 V/s) 185 V | | ||
+ | | | Service life: | | ||
+ | | | 150 operations 8/20 μs 250 A, 1.2/50, 500 V (IEC61643-21) | | ||
+ | | | 20 operations 2/10 μs, 5 kV, 500 A | | ||
+ | | | 2 operations 8/20 μs, 1 kA | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Mechanical parameters ^ | | ||
+ | |Dimensions | 71.6 x 89.7 x 62.2 mm | | ||
+ | |Mounting | DIN rail | | ||
+ | |Screw terminals | 05 mm² - 15 mm² cable cores | | ||
+ | |Operating temperature | 0 .. +70 °C | | ||
+ | |LED diodes | Status, RS485, Sensors | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Extension options | | | ||
+ | |Interface | HBUS (DIN rail, bottom pluggable, no external wires needed) | | ||
+ | |Extension modules | SM2-PC, SM2-AD, SM2-DI, SM2-GSM, SM2-BE | | ||
+ | |||
+ | |||
+ | < | ||
+ | \\ | ||
+ | < | ||
+ | \\ | ||
+ | < | ||
+ | \\ | ||
+ | < | ||
+ | \\ | ||
+ | < | ||
+ | |||
+ | |||
+ | \\ |