- | ===== Monitoring and Alarms ===== | + | ===== Alerts ===== |
Line 5: | Line 5: | ||
- | Menu Monitoring and alarms enables selecting the way of informing the user about alarms.\\ | + | Menu Alerts enables selecting the way of informing the user about alarms.\\ |
\\ | \\ | ||
- | {{ :en:sim:manual:dohled_a_upozorneni:monitoring_a_alarmy.png?nolink& }} | + | {{ .:monitoring_a_alarmy.png?direct }} |
- | ==== PV plant monitoring ==== | + | ==== PV Plant Monitoring ==== |
- | Table shows monitored components of a PV plant, their current status and limit values. It enables setting up the way of informing the user about alarms via e-mail or SMS. You can set up the limit values in the v menu "System set up%%\%%Sensors and alarms", see chapter 4.1.3 Sensors and alarms.\\ | + | Table shows monitored components of a PV plant, their current status and limit values. It enables setting up the way of informing the user about alarms via e-mail or SMS. You can set up the limit values of sensors in the v menu "System set up%%\%%Sensors and alarms", see chapter 4.1.3 Sensors & Alerts.\\ |
- | \\ | + | |
- | **Loading pulses from the electrometer** \\ | + | |
- | Production is monitored continuously. If no pulses come from the electrometer, countdown starts. When limit value is exceeded, notification is sent to the user.\\ | + | |
- | \\ | + | |
- | **Communication with the inverter** \\ | + | |
- | Inverter's response on line RS-485 is monitored continuously. If there is no response, countdown starts. When limit value is exceeded, notification is sent to the user.\\ | + | |
\\ | \\ | ||
**Sensors** \\ | **Sensors** \\ | ||
- | If any sensor connected to the unit exceeds the limit values, a notification to the user is sent. <WRAP info> Sensors in default setting have 60 seconds delay, inverters 5 seconds delay. Further info on setting up the delay in chapter 4.1.3 Sensors and alarms. </WRAP> **Inputs** \\ | + | If any sensor connected to the unit exceeds the limit values, a notification to the user is sent. <WRAP info> Sensors in default setting have 60 seconds delay, inverters 5 seconds delay. Further info on setting up the delay in chapter 4.1.3 Sensors and alarms. </WRAP> |
+ | **Inputs** \\ | ||
When input status (connected / disconnected) changes in a way not allowed by the user, a notification to the user is sent immediately.\\ | When input status (connected / disconnected) changes in a way not allowed by the user, a notification to the user is sent immediately.\\ | ||
\\ | \\ | ||
Line 29: | Line 24: | ||
\\ | \\ | ||
**Sending production report** \\ | **Sending production report** \\ | ||
- | A production report (selected type of message) is sent to the user in preset intervals.\\ | + | A production report (selected type of message) is sent to the user in preset intervals.\\ \\ |
- | ==== Inverter status ==== | + | ==== Devices State ==== |
- | + | If a failure is detected at the device (e.g. inverter), a notification to the user is sent immediately. | |
- | + | ||
- | If a failure is detected at the inverter ("status" bar), a notification to the user is sent immediately. | + | |