-Solar Monitor has 3 digital inputs DI. It is easy to connect movement sensor, surge, optical barrier, door sensor and various other devices that use contact inputs to indicate its status. ​Input DI3 can be used for measuring energy at the [[:​en:​sim:​manual:​jak_na_instalaci:elmer|electro meter]] on condition that it has pulse output SO.+Solar Monitor has 3 digital inputs DI. It is easy to connect movement sensor, surge, optical barrier, door sensor and various other devices that use contact inputs to indicate its status. ​Any of the inputs DI1, DI2, DI3 can be used for measuring energy at the [[.:elmer|electrometer]] on condition that it has pulse output SO.
  
  
Line 14: Line 14:
  
  
-Conversion coefficient differs according to the electrometer'​s type and in most cases it doesn'​t correspond with the number of LED diode pulses. It is very important to select the right coefficient for SO output. Most electrometers have 250/kwh number of pulses at the LED diode and 1000/kwh at the output SO. You will find out how to enter the right coefficient into Solar Monitor unit in chapter [[:sim:manual:​menu_nastaveni:​stridace_a_mereni|Inverters and measuring]].+Conversion coefficient differs according to the electrometer'​s type and in most cases it doesn'​t correspond with the number of LED diode pulses. It is very important to select the right coefficient for SO output. Most electrometers have 250/kwh number of pulses at the LED diode and 1000/kwh at the output SO. You will find out how to enter the right coefficient into Solar Monitor unit in chapter [[..:​menu_nastaveni:​vstupy_a_vystupy|Inputs & Counters]].
  
  
Line 22: Line 22:
 It is possible to connect more devices to a single contact loop and monitor the entire circuit as one name. But if one device changes contact status, you won't be able to identify which device has caused the alarm.\\ ​ It is possible to connect more devices to a single contact loop and monitor the entire circuit as one name. But if one device changes contact status, you won't be able to identify which device has caused the alarm.\\ ​
 \\  \\ 
-{{  ​:​sim:​manual:​jak_na_instalaci:​digitalni_vstupy.png?​nolink&​400 ​ }}+{{  ​.:​digitalni_vstupy.png?​nolink&​400 ​ }}
  
  
Line 30: Line 30:
 You can choose one relay which is in SM2-MU. The relay can switch on the ventilation according to current ambiente temperature or it can control the boiler (must be connected via contactor) according to the current energy production etc.\\ ​ You can choose one relay which is in SM2-MU. The relay can switch on the ventilation according to current ambiente temperature or it can control the boiler (must be connected via contactor) according to the current energy production etc.\\ ​
 \\  \\ 
-{{  ​:​sim:​manual:​jak_na_instalaci:​digitalni_vystupy.png?​nolink&​400 ​ }}+{{  ​.:​digitalni_vystupy.png?​nolink&​400 ​ }}
  
en/sim/manual/jak_na_instalaci/digitalni_vstupy_a_vystupy.1408110590.txt.gz ยท Last modified: 2014/08/15 15:49 by jitka