en:sim:manual:popis:parametry_zakladniho_modulu
no way to compare when less than two revisions
Rozdíly
Zde můžete vidět rozdíly mezi vybranou verzí a aktuální verzí dané stránky.
Předchozí verzeNásledující verze | |||
— | en:sim:manual:popis:parametry_zakladniho_modulu [2016/10/07 15:47] – ondra | ||
---|---|---|---|
Řádek 1: | Řádek 1: | ||
+ | ===== Basic module parameters ===== | ||
+ | |||
+ | |||
+ | ---- | ||
+ | |||
+ | |||
+ | {{ .: | ||
+ | |||
+ | |||
+ | ^Max. number of devices ^ | | ||
+ | |SM2-MU Basic and SM2-MU Start| | ||
+ | |SM2-MU 60 | 6 devices | | ||
+ | |SM2-MU 300 | 30 devices | | ||
+ | |SM2-MU 1000 | 100 devices | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Supported devices ^ Ethernet or serial bus connected | | ||
+ | |Communication | Ethernet (TCP), up to 3 serial ports | | ||
+ | |Inverter protocols | AEG, Carlo Gavazzi, Danfoss, Delta, Diehl, Fronius, IBC Solar, Kaco, Kostal, Mastervolt, Morningstar, | ||
+ | |Meter protocols | ABB (REX521), Carlo Gavazzi (VMU-E/X), Fronius (Smart Meter), KMB (SMC-144, PA-144), Phoenix Contact (MA200/ | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Sensors ^ Dallas 1-wire bus | | ||
+ | |Interface | Screw terminals for 05 mm² - 15 mm² cores | | ||
+ | |Max. count | 10 sensors | | ||
+ | |Max. distance | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Ethernet interface (LAN) ^ | | ||
+ | |Interface | RJ45 (100BASE-T) -100Mbit/s, compatible with networks 10/100/1000 Mbit/s, auto MDIX | | ||
+ | |Protocols | HTTP, SOAP, DNS, UDP Setup, Telnet, ARP, ICMP, SMTP, SNMP, Modbus | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^RS485 / RS422 / RS232 ^ | | ||
+ | |Interfaces | ||
+ | | | | | ||
+ | | | __// | ||
+ | | | 2x RS485 or 1x RS422 opto-isolated | | ||
+ | | | 1x RS485 + 1x RS232 | | ||
+ | | | 1x RS485 + 1x RS232 opto-isolated | | ||
+ | | | | | ||
+ | | | //__SM2-BE extension module__// | | ||
+ | | | 1x RS232 + 1x RS485 surge protected | | ||
+ | | | | | ||
+ | |Speed | ||
+ | |Termination | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Inputs | opto-electronically isolated | | ||
+ | |Interface | HBUS | | ||
+ | |Usage | SM2-PC, SM2-AD, SM2-DI, SM2-GSM | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Inputs (opto-electronic separated) | | | ||
+ | |Interface | bus 0,5 mm² - 1,5 mm², 2 inputs, 1 electrometer SO connection | | ||
+ | |Max. distance | 30m | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Output | 1 x relay (32 V, 3 A), with power fuse | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Mechanical parametres | | | ||
+ | |Dimensions | 71,6 x 89,7 x 62,2 mm | | ||
+ | |Operating temperature | 0 up to + 70 °C | | ||
+ | |LED diodes | Status, RS485, Sensors | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Power parameters | | | ||
+ | |power supply | 9-35 V, typ. 1,2 W | | ||
+ | |DI1, DI2, DI3 | 8-80 V | | ||
+ | |1 Wire | max. cable lenght 100 m, ext. 5 V, max. 350 mA, with power fuse 500 mA | | ||
+ | |RS485 | | | ||
+ | |||
+ | |||
+ | \\ | ||
en/sim/manual/popis/parametry_zakladniho_modulu.txt · Poslední úprava: 2017/08/10 09:56 autor: ondra