+ | ===== Basic module parameters ===== | ||
+ | |||
+ | |||
+ | ---- | ||
+ | |||
+ | |||
+ | {{ .: | ||
+ | |||
+ | |||
+ | ^Max. number of devices< | ||
+ | |SM2-MU Basic and SM2-MU Start| | ||
+ | |SM2-MU 60 | 6 devices< | ||
+ | |SM2-MU 300 | 30 devices< | ||
+ | |SM2-MU 1000 | 100 devices< | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Supported devices< | ||
+ | |Communication | Ethernet (TCP), up to 3 serial ports | | ||
+ | |Inverter protocols | AEG, Carlo Gavazzi, Danfoss, Delta, Diehl, Fronius, IBC Solar, Kaco, Kostal, Mastervolt, Morningstar, | ||
+ | |Meter protocols | ABB (REX521), Carlo Gavazzi (VMU-E/X), Fronius (Smart Meter), KMB (SMC-144, PA-144), Phoenix Contact (MA200/ | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Sensors ^ Dallas 1-wire bus | | ||
+ | |Interface | Screw terminals for 05 mm² - 15 mm² cores | | ||
+ | |Max. count | 10 sensors | | ||
+ | |Max. distance | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Ethernet interface (LAN) ^ ^ | ||
+ | |Interface | RJ45 (100BASE-T) -100Mbit/s, compatible with networks 10/100/1000 Mbit/s, auto MDIX | | ||
+ | |Protocols | HTTP, SOAP, DNS, UDP Setup, Telnet, ARP, ICMP, SMTP, SNMP, Modbus | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^RS485 / RS422 / RS232 ^ ^ | ||
+ | |Interfaces | ||
+ | | | | | ||
+ | | | __// | ||
+ | | | 2x RS485 or 1x RS422 opto-isolated< | ||
+ | | | 1x RS485 + 1x RS232 | | ||
+ | | | 1x RS485 + 1x RS232 opto-isolated | | ||
+ | | | | | ||
+ | | | //__SM2-BE extension module__// | | ||
+ | | | 1x RS232 + 1x RS485 surge protected< | ||
+ | | | | | ||
+ | |Speed | ||
+ | |Termination | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Inputs ^ opto-electronically isolated ^ | ||
+ | |3x digital inputs (DI) | software configurable between dry contact or S0 pulse meter inputs (e.g. from electrometer) | | ||
+ | |Max. distance | 30 m (depends on cable) | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Outputs ^ ^ | ||
+ | |1x relay | 32 V, 3 A, protected with power fuse | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Electrical parameters ^ ^ | ||
+ | |Power supply | 9-35 V DC, typ. 1.2 W @ 12V | | ||
+ | |DI1, DI2, DI3 | 8-80 V | | ||
+ | |1 Wire | Interface provides 5 V power supply, max. 350 mA, protected with 500 mA power fuse. | | ||
+ | |RS485 | Protected against transient voltages above 6.8V and against high currents with 10Ω resistors. Additional surge protection can be achieved with SM2-BE (bus extension) module with gas discharge tubes: | | ||
+ | | | Minimum DC Sparkover (100 V/s) 185 V | | ||
+ | | | Service life: | | ||
+ | | | 150 operations 8/ | ||
+ | | | 20 operations 2/ | ||
+ | | | 2 operations 8/ | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Mechanical parameters ^ ^ | ||
+ | |Dimensions | ||
+ | |Mounting | ||
+ | |Screw terminals | ||
+ | |Operating temperature | ||
+ | |LED diodes | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Extension options | | | ||
+ | |Interface | ||
+ | |Extension modules | ||
+ | \\ | ||
+ | 1 ... A device represents an inverter, stringbox, MPP tracker, battery monitor, meter or any other | ||
+ | 2 ... Can be configured by software (web UI, XML). \\ | ||
+ | 3 ... Piggy-back functionality replaces the “2x RS485 or 1x RS422” interface. \\ | ||
+ | 4 ... SM2-BE is mutually exclusive to the SM2-GSM usage. 2x SM2-BE modules can be also used to extend the HBUS connection between SM2 modules. \\ | ||
+ | 5 ... Communication speeds are available according to selected device communication protocols. \\ | ||
+ | |||
en/sim/manual/popis/parametry_zakladniho_modulu.txt · Poslední úprava: 2017/08/10 09:56 autor: ondra