+ | ===== Installation, | ||
+ | |||
+ | |||
+ | ---- | ||
+ | |||
+ | |||
+ | Module installation to be found [[: | ||
+ | \\ | ||
+ | \\ | ||
+ | With analog inputs AI1 and AI2 the ranges of:\\ | ||
+ | 0 - 20 mA a 0 - 10 V are available for voltage or current measuring.\\ | ||
+ | \\ | ||
+ | With analog input AI3 the ranges of:\\ | ||
+ | 0 - 20 mA, 0 - 10 V, 0 - 20mV, 0 - 100 mV are available for voltage or current measuring.\\ | ||
+ | \\ | ||
+ | Measurement ranges are set up before module is delivered! Correct specification when you order SM2-AD module is essential. It is possible to connect | ||
+ | \\ | ||
+ | {{ : | ||
+ | \\ | ||
+ | Analog output A0 to be connected in the same way. Voltage of 0-10V is detected at output terminals depending on current production or temperature. It can be used for continuous regulation of appliances, e.g. ventilation fan.\\ | ||
+ | \\ | ||
+ | {{ : | ||
+ | \\ | ||
+ | Digitální (relé) výstupy DO připojíme obdobně jako u SM2-MU. Tedy např. k boileru nebo akumulačním kamnům dle obrázku.\\ | ||
+ | \\ | ||
+ | {{ : | ||
+ | \\ | ||
+ | <WRAP right> [[: | ||