User Tools

Site Tools


en:sim:manual:rozsirujici_moduly:sm2_pc

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

en:sim:manual:rozsirujici_moduly:sm2_pc [2016/11/15 15:49]
ondra
en:sim:manual:rozsirujici_moduly:sm2_pc [2018/06/25 15:43] (current)
ondra
Line 17: Line 17:
 As soon as the modules are connected and Solar Monitor unit is connected to the power supply, a green LED diode indicating status should glow. In case it doesn'​t glow, check if module is connected to SM2-MU. Open menu "​System set up / Power control"​ in you browser. You have to set up inputs combinations and relevant power control values in % or cos φ here.\\ ​ As soon as the modules are connected and Solar Monitor unit is connected to the power supply, a green LED diode indicating status should glow. In case it doesn'​t glow, check if module is connected to SM2-MU. Open menu "​System set up / Power control"​ in you browser. You have to set up inputs combinations and relevant power control values in % or cos φ here.\\ ​
 \\  \\ 
-{{  .:​pc-spusteni_a_konfigurace.png?​nolink& ​ ​}}\\ ​+{{  .:​pc-spusteni_a_konfigurace.png?​direct ​ ​}}\\ ​
 If you wish to use PC module for more Solar Monitor units, select option "​Remote"​ in menu "Power control source"​ for each unit. Fill in the address of SM2-MU, where the power control module is connected. .\\  If you wish to use PC module for more Solar Monitor units, select option "​Remote"​ in menu "Power control source"​ for each unit. Fill in the address of SM2-MU, where the power control module is connected. .\\ 
 \\  \\ 
-{{  .:​pc-vzdaleny_modul.png?​nolink& ​ }} +{{  .:​pc-vzdaleny_modul.png?​direct ​ }} 
- +\\ \\ 
- +{{ .:​vzdalene_ovladani_vykonu.png?​direct |}} 
-\\ +\\ \\ 
 +==== The example how to connect the SM2-MU to PLC Tecomat Foxtrot by Teco ==== 
 +__Connection__ 
 +{{ .:​pc-foxtrot_sm_pc.png?​direct |}} \\ \\ 
 +__Configuration for 32 values of power control__ 
 +{{ .:​32_stupnu_rizeni_vykonu.png?​direct |}} 
 +\\ \\
 ==== Specification ==== ==== Specification ====
-\\  
 <WRAP half column> <WRAP half column>
 ^Binary inputs |  2 x 5 inputs with usual Vcc a GND | ^Binary inputs |  2 x 5 inputs with usual Vcc a GND |
Line 44: Line 48:
 |  |  | |  |  |
 ^Power supply |  12 – 24 V DC, max 100 mA | ^Power supply |  12 – 24 V DC, max 100 mA |
 +^  ^  |
 +|  |  |
 +^Degree of protection |  IP20 |
 ^  ^  | ^  ^  |
 |  |  | |  |  |