Řádek 5: | Řádek 5: | ||
- | DI module increases the number of unit's digital inputs significantly and enables connecting other devices.\\ | + | DI module increases the number of unit's digital inputs significantly and enables connecting other devices.\\ |
\\ | \\ | ||
- | {{ .: | + | ==== Connecting digital inputs ==== |
\\ | \\ | ||
+ | Module SM2-DI has 10 digital inputs. Digital inputs DI can be connected in the same way as inputs to SM2-MU. You can easily connect movement sensor, surge, optical barrier, door sensor and other devices that use contact output to indicate its status.\\ | ||
\\ | \\ | ||
+ | There are two ways of wiring.\\ | ||
\\ | \\ | ||
- | **Technical specification** | + | The first one requires connecting terminal DC- to SM2-MU with relevant terminal DCOM at the module SM2-DI. One terminal DCOM goes with inputs DI1–DI5 and the second terminal with inputs DI6–DI10. In order to start the input, signal DC+ from SM2-MU unit has to be connected to relevant terminal of SM2-DI terminal.\\ |
+ | \\ | ||
+ | {{ .: | ||
+ | \\ | ||
+ | For the second type of wiring, where inputs of SM2-DI module use external power supply (see the following picture), voltage has to be in the range of 8-80 V.\\ | ||
+ | \\ | ||
+ | {{ .: | ||
+ | \\ | ||
+ | ==== Start and configuration ==== | ||
+ | \\ | ||
+ | When you have connected the modules and Solar Monitor unit has been connected to the power supply, green LED diode indicating status should glow. If it doesn' | ||
+ | Open menu “Settings / Inputs & Counters” in your browser. | ||
+ | |||
+ | |||
+ | Select limit values for relevant connected inputs.\\ | ||
+ | \\ | ||
+ | {{ .: | ||
+ | It is possible to choose the type of message (e-mail, SMS) that informs the user of changes in input values.\\ | ||
+ | \\ | ||
+ | ==== Technical specification ==== | ||
+ | <WRAP half column> | ||
^Binary inputs | 2 x 5 inputs with standard Vcc and GND | | ^Binary inputs | 2 x 5 inputs with standard Vcc and GND | | ||
^ ^ | | ^ ^ | | ||
Řádek 30: | Řádek 52: | ||
| | | | | | | | ||
^Power supply | 12 – 24 V DC, max 100 mA | | ^Power supply | 12 – 24 V DC, max 100 mA | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Degree of protection | IP20 | | ||
^ ^ | | ^ ^ | | ||
| | | | | | | | ||
^Temperature range | -25 °C to +60 °C | | ^Temperature range | -25 °C to +60 °C | | ||
- | + | </ | |
- | + | <WRAP half column> | |
- | \\ | + | {{ .:moduly_vykres.png? |
- | \\ | + | </WRAP> |
- | **Connecting digital inputs** \\ | + | |
- | \\ | + | |
- | Module SM2-DI has 10 digital inputs. Digital inputs DI can be connected in the same way as inputs to SM2-MU. You can easily connect movement sensor, surge, optical barrier, door sensor and other devices that use contact output to indicate its status.\\ | + | |
- | \\ | + | |
- | There are two ways of wiring.\\ | + | |
- | \\ | + | |
- | The first one requires connecting terminal DC- to SM2-MU with relevant terminal DCOM at the module SM2-DI. One terminal DCOM goes with inputs DI1–DI5 and the second terminal with inputs DI6–DI10. In order to start the input, signal DC+ from SM2-MU unit has to be connected to relevant terminal of SM2-DI terminal.\\ | + | |
- | \\ | + | |
- | {{ .:di-zapojeni_1.png? | + | |
- | \\ | + | |
- | For the second type of wiring, where inputs of SM2-DI module use external power supply (see the following picture), voltage has to be in the range of 8-80 V.\\ | + | |
- | \\ | + | |
- | {{ .: | + | |
- | \\ | + | |
- | **Start and configuration** \\ | + | |
- | \\ | + | |
- | When you have connected the modules and Solar Monitor unit has been connected to the power supply, green LED diode indicating status should glow. If it doesn' | + | |
- | + | ||
- | + | ||
- | Open menu “System set up/ Inputs and Outputs” in your browser. | + | |
- | + | ||
- | + | ||
- | Select limit values for relevant connected inputs.\\ | + | |
- | \\ | + | |
- | {{ .: | + | |
- | Tick the box to choose the type of message (e-mail, SMS) that informs the user of changes in input values.\\ | + | |
- | \\ | + | |
- | {{ .: | + | |
- | + | ||
- | + | ||
- | \\ | + |
en/sim/manual/rozsirujici_moduly/sm2_di.txt · Poslední úprava: 2018/06/25 13:43 autor: ondra