-===== Inputs and Measurement =====+===== Inputs & Meters =====
  
  
Řádek 5: Řádek 5:
  
  
-In SM2-RM go to menu System Setup/Inputs and Measurement.\\  +In SM2-RM go to menu System Setup/Inputs & Meters.\\ 
-\\  +
-{{  :en:sim:rm:web_zarizeni:vstupy_a_mereni_3citace.png?nolink&  }}\\ +
 \\  \\ 
 +{{  .:vstupy_a_mereni_3citace.png?nolink&  }}\\ 
 ==== Input 1, Input 2, Input 3 ==== ==== Input 1, Input 2, Input 3 ====
  
Řádek 15: Řádek 14:
 Assign each input its function.\\  Assign each input its function.\\ 
 \\  \\ 
-If you assign input **Counting ** function, it will count pulses.\\ +If you assign input **Counter ** function, it will count pulses.\\ 
 <WRAP info> You can erase pulse score by changing energy correction, by changing input function (Reader, Inactive) or by pressing a reset button for 4 sec. The reset button is at the top of the box bellow Status diode. You can use e.g. a paper clip to press the button. </WRAP> If you choose **Input** function, there will be value 1 or 2 (connected, disconnected) in "Overview".\\  <WRAP info> You can erase pulse score by changing energy correction, by changing input function (Reader, Inactive) or by pressing a reset button for 4 sec. The reset button is at the top of the box bellow Status diode. You can use e.g. a paper clip to press the button. </WRAP> If you choose **Input** function, there will be value 1 or 2 (connected, disconnected) in "Overview".\\ 
 \\  \\ 
Řádek 35: Řádek 34:
 <WRAP info> Default setting is reading pulses from the electro meter, value 1000 pulses per 1 kWh. If your electro meter shows a different number, change the setting. </WRAP> <WRAP half column>\\  <WRAP info> Default setting is reading pulses from the electro meter, value 1000 pulses per 1 kWh. If your electro meter shows a different number, change the setting. </WRAP> <WRAP half column>\\ 
 The number of impulses per 1 kWh is usually between 250-1000 imp/1kWh. In case there are 2 possible numbers of impulses at your electro meter, the lower number is usually the right one for the SO output.\\  The number of impulses per 1 kWh is usually between 250-1000 imp/1kWh. In case there are 2 possible numbers of impulses at your electro meter, the lower number is usually the right one for the SO output.\\ 
-The higher number tells you how often a LED diode at your electro meter switches on. </WRAP> <WRAP half column> {{  :en:sim:rm:rychly_navod:jak_na_to:obrazek_elmeru.png?100  }}</WRAP>\\ +The higher number tells you how often a LED diode at your electro meter switches on. </WRAP> <WRAP half column> {{  ..:rychly_navod:jak_na_to:obrazek_elmeru.png?100  }}</WRAP>\\ 
 **In case you need to setup number of pulses other than 1000 per 1 kWh než 1000, it is essential to differentiate between direct and indirect measurement:**  **In case you need to setup number of pulses other than 1000 per 1 kWh než 1000, it is essential to differentiate between direct and indirect measurement:** 
 ==== 1. Direct Measuring ==== ==== 1. Direct Measuring ====
Řádek 53: Řádek 52:
 \\  \\ 
 </WRAP> <WRAP half column>\\  </WRAP> <WRAP half column>\\ 
-{{  :en:sim:rm:rychly_navod:jak_na_to:pocet_pulzu_pomer.png?200  }}\\ +{{  ..:rychly_navod:jak_na_to:pocet_pulzu_pomer.png?200  }}\\ 
 \\  \\ 
 \\  \\ 
Řádek 68: Řádek 67:
 \\  \\ 
 //Example of another input function:// \\  //Example of another input function:// \\ 
-{{  :en:sim:rm:web_zarizeni:vstupy_a_mereni_vice_moznosti.png?nolink&  }}+{{  .:vstupy_a_mereni_vice_moznosti.png?nolink&  }}
  
en/sim/rm/web_zarizeni/vstupy_a_mereni.txt · Poslední úprava: 2014/09/11 10:16 autor: ondra