Uživatelské nástroje

Nástroje pro tento web


en:sim:manual:jak_na_instalaci:elmer

Rozdíly

Zde můžete vidět rozdíly mezi vybranou verzí a aktuální verzí dané stránky.

Odkaz na výstup diff

Obě strany předchozí revizePředchozí verze
Následující verze
Předchozí verze
en:sim:manual:jak_na_instalaci:elmer [2014/08/22 13:06] dusanen:sim:manual:jak_na_instalaci:elmer [2019/12/06 10:57] (aktuální) ondra
Řádek 8: Řádek 8:
  
  
-Solar Monitor can be connected to Green Bonus electro meter with binary input DI3. It reads the energy output of your PV plant.\\ +Solar Monitor can be connected to Green Bonus electro meter via any of three binary inputs DI. It reads the energy output of your PV plant.\\ 
 \\  \\ 
 //The following picture shows how to connect to the electro meter with S0 (puls) output:// \\  //The following picture shows how to connect to the electro meter with S0 (puls) output:// \\ 
 \\  \\ 
-{{  :en:sim:manual:jak_na_instalaci:elektromer.png?nolink&  }}\\ +{{  .:elektromer.png?nolink&  }}\\ 
 \\  \\ 
 In order to get the right data, the right number of pulses per 1 kWh must be set up in the unit.\\  In order to get the right data, the right number of pulses per 1 kWh must be set up in the unit.\\ 
Řádek 21: Řádek 21:
  
  
-In the electro meter's label or documentation find out how many pulses per 1 kWh your electro meter generates at the SO output. Fill in this value into relevant box in SM2-MU menu [[:en:sim:manual:menu_nastaveni:stridace_a_mereni|Inverters and measuring]].+In the electro meter's label or documentation find out how many pulses per 1 kWh your electro meter generates at the SO output. Fill in this value into relevant box in SM2-MU menu [[..:menu_nastaveni:vstupy_a_vystupy|Inputs & Counters]].
  
  
Řádek 32: Řádek 32:
  
  
-Look at the indirect power measuring transformer (1 transformer connected to each phase) and find a ratio (e.g. 150A/5A). Use the result of this ratio (30 in this example) in the formula (10 000/30). Fill in the result into relevant box in SM2-MU menu  [[:en:sim:manual:menu_nastaveni:stridace_a_mereni|Inverters and measuring]].+Look at the indirect power measuring transformer (1 transformer connected to each phase) and find a ratio (e.g. 150A/5A). Use the result of this ratio (30 in this example) in the formula (10 000/30). Fill in the result into relevant box in SM2-MU menu  [[..:menu_nastaveni:vstupy_a_vystupy|Inputs & Counters]].
  
  
Řádek 38: Řádek 38:
 <WRAP info> In case you want the electro meter connected to the Solar Monitor and use pulse output for another device (e.g. Wattrouter) at the same time, follow instruction in the next picture: </WRAP>\\  <WRAP info> In case you want the electro meter connected to the Solar Monitor and use pulse output for another device (e.g. Wattrouter) at the same time, follow instruction in the next picture: </WRAP>\\ 
 \\  \\ 
-{{  :en:sim:manual:jak_na_instalaci:wattrouter_a_elmer.png?nolink&  }}+{{  .:wattrouter_a_elmer.png?nolink&  }}
  
en/sim/manual/jak_na_instalaci/elmer.1408705560.txt.gz · Poslední úprava: 2014/08/22 13:06 autor: dusan