Uživatelské nástroje

Nástroje pro tento web


en:sim:manual:menu_nastaveni:stridace_a_mereni:ethernet

Rozdíly

Zde můžete vidět rozdíly mezi vybranou verzí a aktuální verzí dané stránky.

Odkaz na výstup diff

Obě strany předchozí revizePředchozí verze
Následující verze
Předchozí verze
en:sim:manual:menu_nastaveni:stridace_a_mereni:ethernet [2014/08/06 15:48] jitkaen:sim:manual:menu_nastaveni:stridace_a_mereni:ethernet [2018/06/11 09:30] (aktuální) ondra
Řádek 9: Řádek 9:
 \\  \\ 
 \\  \\ 
-To be set up in the submenu Inverters and Measuring </WRAP> <WRAP half column> {{  :en:sim:manual:rychly_navod:jak_na_to:stridace_a_mereni.png?100  }}\\ +To be set up in the submenu Find Devices </WRAP> <WRAP half column> {{  ..:..:rychly_navod:jak_na_to:detekce_zarizeni.png?100  }}\\ 
 </WRAP> **Type of protocol** \\  </WRAP> **Type of protocol** \\ 
 <WRAP half column>\\  <WRAP half column>\\ 
 \\  \\ 
-Select the manufacturer of your inverter. </WRAP> <WRAP half column> {{  :en:sim:manual:menu_nastaveni:stridace_a_mereni:ethernet.png  }}</WRAP>\\ +Select the manufacturer of your inverter. </WRAP> <WRAP half column> {{  .:ethernet.png  }}</WRAP>\\ 
 \\  \\ 
 <WRAP info> Setting up network interface has two address modes:\\  <WRAP info> Setting up network interface has two address modes:\\ 
-1. IP Address\\  +1. IP Address - communication in local network \\  
-2. Port\\ +2. Port - remote communication via public IP address of router with translation of addresses (NAT) \\ 
 </WRAP>\\  </WRAP>\\ 
 ==== IP Address Detection of Inverters ==== ==== IP Address Detection of Inverters ====
  
  
-Use this type of detection for inverters with different IP addresses.\\ +Use this type of detection if inverters and Solar Monitor are in the same local network.\\ 
 \\  \\ 
 <WRAP info> Address the inverters first. Assign consequent IP addresses to the inverters and the port number. The port number is the same for all inverters. Further info on how to address the inverters to be found in inverter's documentation. </WRAP>\\  <WRAP info> Address the inverters first. Assign consequent IP addresses to the inverters and the port number. The port number is the same for all inverters. Further info on how to address the inverters to be found in inverter's documentation. </WRAP>\\ 
Řádek 29: Řádek 29:
 Enter inverter with the lowest IP address in the network. Detection starts with this address and searches for following higher IP addresses until the required number of destinations has been searched.\\  Enter inverter with the lowest IP address in the network. Detection starts with this address and searches for following higher IP addresses until the required number of destinations has been searched.\\ 
 \\  \\ 
-{{  :en:sim:manual:menu_nastaveni:stridace_a_mereni:eth_ip_adresa.png?350}}**Port** \\ +{{  .:eth_ip_adresa.png?350}}**Port** \\ 
 Enter port's number.\\  Enter port's number.\\ 
 \\  \\ 
Řádek 42: Řádek 42:
 \\  \\ 
 **Read Connected Inverters** \\  **Read Connected Inverters** \\ 
-Click on button{{:en:sim:manual:rychly_navod:jak_na_to:nacist_stridace.png?nolink&}}to detect inverters connected to SM2-MU\\ +Click on button {{..:..:rychly_navod:jak_na_to:automaticka_detekce.png?nolink&}} to detect inverters connected to SM2-MU\\ 
 \\  \\ 
-Detection can take up to several minutes depending on the type of protocol and the number of inverters. <WRAP info> To be detected, inverters must be on, i.e. they must have sufficient electric current coming from the PV panels. </WRAP> When detection is finished, the list of connected inverters is displayed. <WRAP half column> </WRAP> <WRAP half column>\\  +Detection can take up to several minutes depending on the type of protocol and the number of inverters. <WRAP info> To be detected, inverters must be on, i.e. they must have sufficient electric current coming from the PV panels. </WRAP> When detection is finished, the list of connected inverters is displayed. \\ \\ 
-\\  +Save changes you have made{{..:..:rychly_navod:jak_na_to:tlacitko_ulozit.png?nolink&}}. \\ \\ 
-\\  +For detailed info on inverter's production, click on a particular inverter in the menu [[..:..:prehledy:prehled_vyroby|Production Overview]].\\ 
-\\  +
-\\  +
-Save changes you have made{{:en:sim:manual:rychly_navod:jak_na_to:tlacitko_ulozit.png?nolink&}}. </WRAP> <WRAP half column> {{  :en:sim:manual:rychly_navod:jak_na_to:ul_zmeny_strid_a_mereni.png?100  }}\\  +
-\\  +
-</WRAP> For detailed info on inverter's production, click on a particular inverter in the menu [[:en:sim:manual:prehledy:prehled_vyroby|Production Overview]].\\ +
 \\  \\ 
 ==== Port Detection of Inverters ==== ==== Port Detection of Inverters ====
  
  
-Use this type of detection for inverters with the same IP address that are located at different ports.\\ +Select this method of detection if **there is a router with network address translation (NAT) between the inverters and the Solar Monitor**. The Solar Monitor will access to the inverters via one router´s address. Assign different, consecutive ports for the local IP addresses of the inverters in the router. If the router is connected to the Internet, router´s IP address must be public. \\ 
 \\  \\ 
-<WRAP info> Address the inverters first. Assign one IP address for all inverters. Assign consequent numbers of ports to inverters. Addressing procedure to be found in inverter's documentation. </WRAP>\\ +<WRAP info> Address the inverters first. Assign different IP addresses to the inverters in your local networkIn the router through which the Solar Monitor will access to the inverters, assign consecutive port numbers to the local IP addresses of the inverters. Further info on how to address the inverters to be found in inverter's documentation. </WRAP>\\ 
 \\  \\ 
 **IP address** \\  **IP address** \\ 
-Enter IP address, the same address for all inverters.\\ +Enter the public IP address which you use for the access to the local network.\\ 
 \\  \\ 
-{{  :en:sim:manual:menu_nastaveni:stridace_a_mereni:eth_port.png?350}}**Port** \\ +{{  .:eth_port.png?350}}**Port** \\ 
 Enter inverter with the lowest port number (destination) at a particular IP address. Detection starts with this port and searches for following higher port numbers until the required number of destinations has been searched.\\  Enter inverter with the lowest port number (destination) at a particular IP address. Detection starts with this port and searches for following higher port numbers until the required number of destinations has been searched.\\ 
 \\  \\ 
Řádek 76: Řádek 71:
 \\  \\ 
 \\  \\ 
-Read connected inverters**\\  +**Read connected inverters**\\  
-Click on button{{:en:sim:manual:rychly_navod:jak_na_to:nacist_stridace.png?nolink&}}to detect inverters connected to SM2-MU.\\  +Click on button{{..:..:rychly_navod:jak_na_to:automaticka_detekce.png?nolink&}}to detect inverters connected to SM2-MU.\\ 
-\\  +
-Detection can take up to several minutes depending on the type of protocol and the number of inverters. <WRAP info> To be detected, inverters must be on, i.e. they must have sufficient electric current coming from the PV panels. </WRAP> When detection is finished, the list of connected inverters is displayed. <WRAP half column> </WRAP> <WRAP half column>\\  +
-\\  +
-\\  +
-\\  +
-\\  +
-Save the changes you have made {{:en:sim:manual:rychly_navod:jak_na_to:tlacitko_ulozit.png?nolink&}}. </WRAP> <WRAP half column> {{  :en:sim:manual:rychly_navod:jak_na_to:ul_zmeny_strid_a_mereni.png?100  }}\\ +
 \\  \\ 
-</WRAP> For detailed info on inverter's production, click on a particular inverter in the menu [[:en:sim:manual:prehledy:prehled_vyroby|Production Overview]].+Detection can take up to several minutes depending on the type of protocol and the number of inverters. <WRAP info> To be detected, inverters must be on, i.e. they must have sufficient electric current coming from the PV panels. </WRAP> When detection is finished, the list of connected inverters is displayed. \\ \\ 
 +Save the changes you have made {{..:..:rychly_navod:jak_na_to:tlacitko_ulozit.png?nolink&}}. \\ \\ 
 +For detailed info on inverter's production, click on a particular inverter in the menu [[..:..:prehledy:prehled_vyroby|Production Overview]].
  
en/sim/manual/menu_nastaveni/stridace_a_mereni/ethernet.1407332924.txt.gz · Poslední úprava: 2014/08/06 15:48 autor: jitka