Uživatelské nástroje

Nástroje pro tento web


en:sim:rm:web_zarizeni:vstupy_a_mereni

Rozdíly

Zde můžete vidět rozdíly mezi vybranou verzí a aktuální verzí dané stránky.

Odkaz na výstup diff

Obě strany předchozí revizePředchozí verze
en:sim:rm:web_zarizeni:vstupy_a_mereni [2014/09/10 14:35] ondraen:sim:rm:web_zarizeni:vstupy_a_mereni [2014/09/11 10:16] (aktuální) ondra
Řádek 7: Řádek 7:
 In SM2-RM go to menu System Setup/Inputs & Meters.\\  In SM2-RM go to menu System Setup/Inputs & Meters.\\ 
 \\  \\ 
-{{  :en:sim:rm:web_zarizeni:vstupy_a_mereni_3citace.png?nolink&  }}\\ +{{  .:vstupy_a_mereni_3citace.png?nolink&  }}\\ 
 ==== Input 1, Input 2, Input 3 ==== ==== Input 1, Input 2, Input 3 ====
  
Řádek 34: Řádek 34:
 <WRAP info> Default setting is reading pulses from the electro meter, value 1000 pulses per 1 kWh. If your electro meter shows a different number, change the setting. </WRAP> <WRAP half column>\\  <WRAP info> Default setting is reading pulses from the electro meter, value 1000 pulses per 1 kWh. If your electro meter shows a different number, change the setting. </WRAP> <WRAP half column>\\ 
 The number of impulses per 1 kWh is usually between 250-1000 imp/1kWh. In case there are 2 possible numbers of impulses at your electro meter, the lower number is usually the right one for the SO output.\\  The number of impulses per 1 kWh is usually between 250-1000 imp/1kWh. In case there are 2 possible numbers of impulses at your electro meter, the lower number is usually the right one for the SO output.\\ 
-The higher number tells you how often a LED diode at your electro meter switches on. </WRAP> <WRAP half column> {{  :en:sim:rm:rychly_navod:jak_na_to:obrazek_elmeru.png?100  }}</WRAP>\\ +The higher number tells you how often a LED diode at your electro meter switches on. </WRAP> <WRAP half column> {{  ..:rychly_navod:jak_na_to:obrazek_elmeru.png?100  }}</WRAP>\\ 
 **In case you need to setup number of pulses other than 1000 per 1 kWh než 1000, it is essential to differentiate between direct and indirect measurement:**  **In case you need to setup number of pulses other than 1000 per 1 kWh než 1000, it is essential to differentiate between direct and indirect measurement:** 
 ==== 1. Direct Measuring ==== ==== 1. Direct Measuring ====
Řádek 52: Řádek 52:
 \\  \\ 
 </WRAP> <WRAP half column>\\  </WRAP> <WRAP half column>\\ 
-{{  :en:sim:rm:rychly_navod:jak_na_to:pocet_pulzu_pomer.png?200  }}\\ +{{  ..:rychly_navod:jak_na_to:pocet_pulzu_pomer.png?200  }}\\ 
 \\  \\ 
 \\  \\ 
Řádek 67: Řádek 67:
 \\  \\ 
 //Example of another input function:// \\  //Example of another input function:// \\ 
-{{  :en:sim:rm:web_zarizeni:vstupy_a_mereni_vice_moznosti.png?nolink&  }}+{{  .:vstupy_a_mereni_vice_moznosti.png?nolink&  }}
  
en/sim/rm/web_zarizeni/vstupy_a_mereni.txt · Poslední úprava: 2014/09/11 10:16 autor: ondra