- | ===== Parametry základního modulu ===== | + | ===== Basic module parameters ===== |
- | ---- | + | |
- | {{ .:sm2_vykres.png?nolink |}} | + | |
- | \\ | + | |
- | ^ Počítačová síť LAN | | | + | |
- | |Rozhraní | RJ45 (100BASE-T)-100Mbit/s, kompatibilní se sítěmi 10/100/1000 Mbit/s| | + | ---- |
- | |Protokoly | HTTP, SOAP, DNS, UDP Setup, Telnet, ARP, ICMP, SMTP| | + | ^Max. number of devices<sup>1</sup> ^ | |
- | ^ ^ ^ | + | |SM2-MU Basic and SM2-MU Start |1 device<sup>1</sup> | |
+ | |SM2-MU 60 |6 devices<sup>1</sup> | | ||
+ | |SM2-MU 300 |30 devices<sup>1</sup> | | ||
+ | |SM2-MU 1000 |100 devices<sup>1</sup> | | ||
+ | ^ ^ | | ||
| | | | | | | | ||
- | ^ Senzory ^ | + | ^Supported devices<sup>1</sup> ^Ethernet or serial bus connected | |
- | |Rozhraní | svorkovnice, dutinky 0,5 mm² - 1,5 mm²| | + | |Communication |Ethernet (TCP), up to 3 serial ports | |
- | |Max. počet | 10 senzorů| | + | |Inverter protocols |AEG, Carlo Gavazzi, Danfoss, Delta, Diehl, Fronius, IBC Solar, Kaco, Kostal, Mastervolt, Morningstar, Omron, Pairan, Power‑One, Refusol, Riello UPS, Santerno, Satcon, Schneider‑Electric, Siemens, Siliken, SMA, Solarmax, Solutronic, Studer, Sungrow, Sunville, Sunways, Vacon, Xantrex | |
- | |Max. vzdálenost | 100 m| | + | |Meter protocols |ABB (REX521), Carlo Gavazzi (VMU-E/X), Fronius (Smart Meter), KMB (SMC-144, PA-144), Phoenix Contact (MA200/250), Schneider‑Electric (SEPAM, PM9), Yorix (GreenBonO), ZPA (IEC 62056-21) | |
- | ^ ^ ^ | + | ^ ^ | |
| | | | | | | | ||
- | ^Střídače | | | + | ^Sensors ^Dallas 1-wire bus | |
- | |Rozhraní | 2 x RS485 nebo 1 x RS422 (softwarově volitelné)| | + | |Interface |Screw terminals for 05 mm² - 15 mm² cores | |
+ | |Max. count |10 sensors | | ||
+ | |Max. distance |100 m, recommended max. cable length for daisy‑chained sensors with minimal trunk segments | | ||
+ | ^ ^ | | ||
| | | | | | | | ||
- | ^Max. počet nadetekovaných střídačů | | | + | ^Ethernet interface (LAN) ^ | |
- | |Solar Monitor Basic a Solar Monitor Start | 1 střídač| | + | |Interface |RJ45 (100BASE-T) -100Mbit/s, compatible with networks 10/100/1000 Mbit/s, auto MDIX | |
- | |Solar Monitor 60 | 6 střídačů| | + | |Protocols |HTTP, SOAP, DNS, UDP Setup, Telnet, ARP, ICMP, SMTP, SNMP, Modbus | |
- | |Solar Monitor 300 | 30 střídačů| | + | ^ ^ | |
- | |Solar Monitor 1000 | 100 střídačů| | + | |
- | ^ ^ ^ | + | |
| | | | | | | | ||
- | ^Terminace | ANO, half i full duplex| | + | ^RS485 / RS422 / RS232 ^ | |
- | ^ ^ ^ | + | |Interfaces |2x RS485 or 1x RS422<sup>2</sup> | |
| | | | | | | | ||
- | ^Možnost rozšíření | | | + | | |__//piggy-back hardware options//__ <sup>3</sup> | |
- | |Rozhraní | HBUS sběrnice| | + | | |2x RS485 or 1x RS422 opto-isolated<sup>2</sup> | |
- | |Použití | SM2-PC, SM2-AD, SM2-DI, SM2-GSM| | + | | |1x RS485 + 1x RS232 | |
- | ^ ^ ^ | + | | |1x RS485 + 1x RS232 opto-isolated | |
| | | | | | | | ||
- | ^Vstupy (opticky oddělené) | | | + | | |//__SM2-BE extension module__ // | |
- | |Rozhraní | svorkovnice 0,5 mm² - 1,5 mm², 2 vstupy, 1 připojení S0 elektroměru| | + | | |1x RS232 + 1x RS485 surge protected<sup>4</sup> | |
- | |Max. vzdálenost | 30m, H=0...500?| | + | |
- | ^ ^ ^ | + | |
| | | | | | | | ||
- | ^Výstup | 1 x relé (32 V, 3 A), jištěno pojistkou| | + | |Speed |300 .. 115.200 bps (software configurable)<sup>2, 5</sup> | |
- | ^ ^ ^ | + | |Termination |Yes, both for half and full duplex, configurable with jumpers | |
+ | ^ ^ | | ||
| | | | | | | | ||
- | ^Fyzické vlastnosti | | | + | ^Inputs ^opto-electronically isolated | |
- | |Rozměry | 71,6 x 89,7 x 62,2 mm| | + | |3x digital inputs (DI) |software configurable between dry contact or S0 pulse meter inputs (e.g. from electrometer) | |
- | |Provozní teplota | 0 až + 70 °C| | + | |Max. distance |30 m (depends on cable) | |
- | |LED kontrolky | Status, RS485, Sensors| | + | ^ ^ | |
- | ^ ^ ^ | + | |
| | | | | | | | ||
- | ^Elektrické parametry | | | + | ^Outputs ^ | |
- | |Napájení | 9-24 V, max. 3W| | + | |1x relay |32 V, 3 A, protected with power fuse | |
- | |DI1, DI2, DI3 | 8-80 V| | + | ^ ^ | |
- | |1 Wire | max. délka kabeláže 100 m, ext. 5 V, max. 350 mA, jištěno pojistkou 500 mA| | + | | | | |
- | |RS485 | | | + | ^Electrical parameters ^ | |
+ | |Power supply |9-35 V DC, typ. 1.2 W @ 12V | | ||
+ | |DI1, DI2, DI3 |8-80 V | | ||
+ | |1 Wire |Interface provides 5 V power supply, max. 350 mA, protected with 500 mA power fuse. | | ||
+ | |RS485 |Protected against transient voltages above 6.8V and against high currents with 10Ω resistors. Additional surge protection can be achieved with SM2-BE (bus extension) module with gas discharge tubes: | | ||
+ | | |Minimum DC Sparkover (100 V/s) 185 V | | ||
+ | | |Service life: | | ||
+ | | |150 operations 8/20 μs 250 A, 1.2/50, 500 V (IEC61643-21) | | ||
+ | | |20 operations 2/10 μs, 5 kV, 500 A | | ||
+ | | |2 operations 8/20 μs, 1 kA | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Mechanical parameters ^ | | ||
+ | |Dimensions |71.6 x 89.7 x 62.2 mm | | ||
+ | |Mounting |DIN rail | | ||
+ | |Screw terminals |05 mm² - 15 mm² cable cores | | ||
+ | |Degree of protection |IP20 | | ||
+ | |Operating temperature |0 .. +70 °C | | ||
+ | |LED diodes |Status, RS485, Sensors | | ||
+ | ^ ^ | | ||
+ | | | | | ||
+ | ^Extension options | | | ||
+ | |Interface |HBUS (DIN rail, bottom pluggable, no external wires needed) | | ||
+ | |Extension modules |[[..:rozsirujici_moduly:sm2_pc|SM2-PC]], [[..:rozsirujici_moduly:sm2_ad|SM2-AD]], [[..:rozsirujici_moduly:sm2_di|SM2-DI]], [[..:rozsirujici_moduly:sm2_gsm|SM2-GSM]], [[..:rozsirujici_moduly:sm2_be|SM2-BE]] | | ||
+ | |||
+ | <sup>1 … A device represents an inverter, stringbox, MPP tracker, battery monitor, meter or any other device which can be detected on any serial bus or via ethernet communication. </sup> \\ | ||
+ | \\ | ||
+ | <sup>2 … Can be configured by software (web UI, XML). </sup> \\ | ||
+ | \\ | ||
+ | <sup>3 … Piggy-back functionality replaces the “2x RS485 or 1x RS422” interface. </sup> \\ | ||
+ | \\ | ||
+ | <sup>4 … SM2-BE is mutually exclusive to the SM2-GSM usage. 2x SM2-BE modules can be also used to extend the HBUS connection between SM2 modules. </sup> \\ | ||
+ | \\ | ||
+ | <sup>5 … Communication speeds are available according to selected device communication protocols. </sup> | ||
+ | \\ | ||
+ | {{ :en:sim:manual:popis:sm2_vykres.png?nolink& }} | ||