User Tools

Site Tools


en:sim:manual:popis:parametry_zakladniho_modulu

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

en:sim:manual:popis:parametry_zakladniho_modulu [2016/10/07 15:47]
ondra
en:sim:manual:popis:parametry_zakladniho_modulu [2017/08/10 09:56] (current)
ondra
Line 3: Line 3:
  
 ---- ----
- +^Max. number of devices<​sup>​1</​sup> ​^  | 
- +|SM2-MU Basic and SM2-MU Start |1 device<​sup>​1</​sup> ​
-{{  .:​sm2_vykres.png?​nolink& ​ }} +|SM2-MU 60 |6 devices<​sup>​1</​sup> ​
- +|SM2-MU 300 |30 devices<​sup>​1</​sup> ​
- +|SM2-MU 1000 |100 devices<​sup>​1</​sup> ​|
-^Max. number of devices ^  | +
-|SM2-MU Basic and SM2-MU Start| ​ 1 device | +
-|SM2-MU 60 |  6 devices | +
-|SM2-MU 300 |  30 devices | +
-|SM2-MU 1000 |  100 devices |+
 ^  ^  | ^  ^  |
 |  |  | |  |  |
-^Supported devices ^  Ethernet or serial bus connected | +^Supported devices<​sup>​1</​sup> ​^Ethernet or serial bus connected | 
-|Communication |  Ethernet (TCP), up to 3 serial ports | +|Communication |Ethernet (TCP), up to 3 serial ports | 
-|Inverter protocols |  AEG, Carlo Gavazzi, Danfoss, Delta, Diehl, Fronius, IBC Solar, Kaco, Kostal, Mastervolt, Morningstar,​ Omron, Pairan, Power‑One,​ Refusol, Riello UPS, Santerno, Satcon, Schneider‑Electric,​ Siemens, Siliken, SMA, Solarmax, Solutronic, Studer, Sungrow, Sunville, Sunways, Vacon, Xantrex | +|Inverter protocols |AEG, Carlo Gavazzi, Danfoss, Delta, Diehl, Fronius, IBC Solar, Kaco, Kostal, Mastervolt, Morningstar,​ Omron, Pairan, Power‑One,​ Refusol, Riello UPS, Santerno, Satcon, Schneider‑Electric,​ Siemens, Siliken, SMA, Solarmax, Solutronic, Studer, Sungrow, Sunville, Sunways, Vacon, Xantrex | 
-|Meter protocols |  ABB (REX521), Carlo Gavazzi (VMU-E/X), Fronius (Smart Meter), KMB (SMC-144, PA-144), Phoenix Contact (MA200/​250),​ Schneider‑Electric (SEPAM, PM9), Yorix (GreenBonO), ​ZPA (IEC 62056-21) |+|Meter protocols |ABB (REX521), Carlo Gavazzi (VMU-E/X), Fronius (Smart Meter), KMB (SMC-144, PA-144), Phoenix Contact (MA200/​250),​ Schneider‑Electric (SEPAM, PM9), Yorix (GreenBonO), ​ZPA (IEC 62056-21) |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
-^Sensors ^  Dallas 1-wire bus | +^Sensors ^Dallas 1-wire bus | 
-|Interface |  Screw terminals for 05 mm² - 15 mm² cores | +|Interface |Screw terminals for 05 mm² - 15 mm² cores | 
-|Max. count   10 sensors | +|Max. count |10 sensors | 
-|Max. distance ​  100 m, recommended max. cable length for daisy‑chained sensors with minimal trunk segments |+|Max. distance |100 m, recommended max. cable length for daisy‑chained sensors with minimal trunk segments |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
 ^Ethernet interface (LAN) ^  | ^Ethernet interface (LAN) ^  |
-|Interface |  RJ45 (100BASE-T) -100Mbit/s, compatible with networks 10/100/1000 Mbit/s, auto MDIX | +|Interface |RJ45 (100BASE-T) -100Mbit/s, compatible with networks 10/100/1000 Mbit/s, auto MDIX | 
-|Protocols |  HTTP, SOAP, DNS, UDP Setup, Telnet, ARP, ICMP, SMTP, SNMP, Modbus |+|Protocols |HTTP, SOAP, DNS, UDP Setup, Telnet, ARP, ICMP, SMTP, SNMP, Modbus |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
 ^RS485 / RS422 / RS232 ^  | ^RS485 / RS422 / RS232 ^  |
-|Interfaces ​  2x RS485 or 1x RS422 |+|Interfaces |2x RS485 or 1x RS422<​sup>​2</​sup> ​|
 |  |  | |  |  |
-|  |  __//​piggy-back hardware options//__ | +|  |__//​piggy-back hardware options//​__ ​<​sup>​3</​sup> ​
-|  |  2x RS485 or 1x RS422 opto-isolated | +|  |2x RS485 or 1x RS422 opto-isolated<​sup>​2</​sup> ​
-|  |  1x RS485 + 1x RS232 | +|  |1x RS485 + 1x RS232 | 
-|  |  1x RS485 + 1x RS232 opto-isolated |+|  |1x RS485 + 1x RS232 opto-isolated |
 |  |  | |  |  |
-|  |  //__SM2-BE extension module__// | +|  |//__SM2-BE extension module__ // | 
-|  |  1x RS232 + 1x RS485 surge protected |+|  |1x RS232 + 1x RS485 surge protected<​sup>​4</​sup> ​|
 |  |  | |  |  |
-|Speed ​  300 .. 115.200 bps (software configurable) | +|Speed |300 .. 115.200 bps (software configurable)<​sup>​2,​ 5</​sup> ​
-|Termination ​  Yes, both for half and full duplex, configurable with jumpers |+|Termination |Yes, both for half and full duplex, configurable with jumpers |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
-^Inputs ​|  ​opto-electronically isolated | +^Inputs ​^opto-electronically isolated | 
-|Interface ​ ​HBUS ​+|3x digital inputs (DI) |software configurable between dry contact or S0 pulse meter inputs (e.g. from electrometer) ​
-|Usage  ​SM2-PC,​ SM2-AD, SM2-DI, SM2-GSM ​|+|Max. distance ​|30 m (depends on cable) ​|
 ^  ^  | ^  ^  |
 |  |  | |  |  |
-^Inputs (opto-electronic separated) |  | +^Outputs ^  | 
-|Interface ​ bus 0,5 mm² - 1,5 mm², 2 inputs, 1 electrometer SO connection | +|1x relay |32 V3 Aprotected with power fuse |
-|Max. distance |  30m |+
 ^  ^  | ^  ^  |
 |  |  | |  |  |
-^Output |  ​1 ​x relay (32 V, 3 A), with power fuse |+^Electrical parameters ^  
 +|Power supply |9-35 V DC, typ. 1.2 W @ 12V | 
 +|DI1, DI2, DI3 |8-80 
 +|1 Wire |Interface provides 5 V power supplymax. 350 mAprotected ​with 500 mA power fuse. | 
 +|RS485 |Protected against transient voltages above 6.8V and against high currents with 10Ω resistors. Additional surge protection can be achieved with SM2-BE (bus extension) module with gas discharge tubes: | 
 +|  |Minimum DC Sparkover (100 V/s) 185 V | 
 +|  |Service life: | 
 +|  |150 operations 8/20 μs 250 A, 1.2/50, 500 V (IEC61643-21) | 
 +|  |20 operations 2/10 μs, 5 kV, 500 A | 
 +|  |2 operations 8/20 μs, 1 kA |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
-^Mechanical ​parametres |  | +^Mechanical ​parameters ^  | 
-|Dimensions |  71,6 x 89,7 x 62,2 mm | +|Dimensions |71.6 x 89.7 x 62.2 mm 
-|Operating temperature |  up to + 70 °C | +|Mounting |DIN rail | 
-|LED diodes |  Status, RS485, Sensors |+|Screw terminals |05 mm² - 15 mm² cable cores | 
 +|Degree of protection |IP20 
 +|Operating temperature |0 .. +70 °C | 
 +|LED diodes |Status, RS485, Sensors |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
-^Power parameters ​|  | +^Extension options ​|  | 
-|power supply ​ 9-35 Vtyp. 1,2 W +|Interface ​|HBUS (DIN railbottom pluggableno external wires needed) ​
-|DI1, DI2, DI3  8-80 V | +|Extension modules ​|[[..:​rozsirujici_moduly:​sm2_pc|SM2-PC]], [[..:​rozsirujici_moduly:​sm2_ad|SM2-AD]][[..:​rozsirujici_moduly:​sm2_di|SM2-DI]][[..:​rozsirujici_moduly:​sm2_gsm|SM2-GSM]][[..:​rozsirujici_moduly:​sm2_be|SM2-BE]] ​|
-|1 Wire |  maxcable lenght 100 mext5 Vmax350 mAwith power fuse 500 mA | +
-|RS485 |  ​|+
  
  
 +<​sup>​1 … A device represents an inverter, stringbox, MPP tracker, battery monitor, meter or any other device which can be detected on any serial bus or via ethernet communication. </​sup>​ \\ 
 +\\ 
 +<​sup>​2 … Can be configured by software (web UI, XML). </​sup>​ \\ 
 +\\ 
 +<​sup>​3 … Piggy-back functionality replaces the “2x RS485 or 1x RS422” interface. </​sup>​ \\ 
 +\\ 
 +<​sup>​4 … SM2-BE is mutually exclusive to the SM2-GSM usage. 2x SM2-BE modules can be also used to extend the HBUS connection between SM2 modules. </​sup>​ \\ 
 +\\ 
 +<​sup>​5 … Communication speeds are available according to selected device communication protocols. </​sup> ​
 \\ \\
 +{{  :​en:​sim:​manual:​popis:​sm2_vykres.png?​nolink& ​ }}
  
en/sim/manual/popis/parametry_zakladniho_modulu.1475848041.txt.gz · Last modified: 2016/10/07 15:47 by ondra