Differences

This shows you the differences between two versions of the page.

Link to this comparison view

en:sim:manual:popis:parametry_zakladniho_modulu [2016/10/18 09:11]
ondra
en:sim:manual:popis:parametry_zakladniho_modulu [2017/08/10 09:56] (current)
ondra
Line 3: Line 3:
  
 ---- ----
- +^Max. number of devices<​sup>​1</​sup>​ ^  | 
- +|SM2-MU Basic and SM2-MU Start |1 device<​sup>​1</​sup>​ | 
-{{  :​en:​sim:​manual:​popis:​sm2_vykres.png?​nolink& ​ }} +|SM2-MU 60 |6 devices<​sup>​1</​sup>​ | 
- +|SM2-MU 300 |30 devices<​sup>​1</​sup>​ | 
- +|SM2-MU 1000 |100 devices<​sup>​1</​sup>​ |
-^Max. number of devices<​sup>​1</​sup> ​ ^  | +
-|SM2-MU Basic and SM2-MU Start |  1 device<​sup>​1</​sup> ​ +
- SM2-MU 60 |  6 devices<​sup>​1</​sup> ​ +
- SM2-MU 300 |  30 devices<​sup>​1</​sup> ​ +
- SM2-MU 1000 |  100 devices<​sup>​1</​sup> ​ |+
 ^  ^  | ^  ^  |
 |  |  | |  |  |
-^Supported devices<​sup>​1</​sup> ​  Ethernet or serial bus connected | +^Supported devices<​sup>​1</​sup>​ ^Ethernet or serial bus connected | 
- Communication |  Ethernet (TCP), up to 3 serial ports | +|Communication |Ethernet (TCP), up to 3 serial ports | 
- Inverter protocols |  AEG, Carlo Gavazzi, Danfoss, Delta, Diehl, Fronius, IBC Solar, Kaco, Kostal, Mastervolt, Morningstar,​ Omron, Pairan, Power‑One,​ Refusol, Riello UPS, Santerno, Satcon, Schneider‑Electric,​ Siemens, Siliken, SMA, Solarmax, Solutronic, Studer, Sungrow, Sunville, Sunways, Vacon, Xantrex | +|Inverter protocols |AEG, Carlo Gavazzi, Danfoss, Delta, Diehl, Fronius, IBC Solar, Kaco, Kostal, Mastervolt, Morningstar,​ Omron, Pairan, Power‑One,​ Refusol, Riello UPS, Santerno, Satcon, Schneider‑Electric,​ Siemens, Siliken, SMA, Solarmax, Solutronic, Studer, Sungrow, Sunville, Sunways, Vacon, Xantrex | 
- Meter protocols |  ABB (REX521), Carlo Gavazzi (VMU-E/X), Fronius (Smart Meter), KMB (SMC-144, PA-144), Phoenix Contact (MA200/​250),​ Schneider‑Electric (SEPAM, PM9), Yorix (GreenBonO),​ ZPA (IEC 62056-21) |+|Meter protocols |ABB (REX521), Carlo Gavazzi (VMU-E/X), Fronius (Smart Meter), KMB (SMC-144, PA-144), Phoenix Contact (MA200/​250),​ Schneider‑Electric (SEPAM, PM9), Yorix (GreenBonO),​ ZPA (IEC 62056-21) |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
-^Sensors ^  Dallas 1-wire bus | +^Sensors ^Dallas 1-wire bus | 
- Interface |  Screw terminals for 05 mm² - 15 mm² cores | +|Interface |Screw terminals for 05 mm² - 15 mm² cores | 
-|Max. count |  10 sensors | +|Max. count |10 sensors | 
-|Max. distance |  100 m, recommended max. cable length for daisy‑chained sensors with minimal trunk segments |+|Max. distance |100 m, recommended max. cable length for daisy‑chained sensors with minimal trunk segments |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
 ^Ethernet interface (LAN) ^  | ^Ethernet interface (LAN) ^  |
-|Interface |  RJ45 (100BASE-T) -100Mbit/s, compatible with networks 10/100/1000 Mbit/s, auto MDIX | +|Interface |RJ45 (100BASE-T) -100Mbit/s, compatible with networks 10/100/1000 Mbit/s, auto MDIX | 
- Protocols |  HTTP, SOAP, DNS, UDP Setup, Telnet, ARP, ICMP, SMTP, SNMP, Modbus |+|Protocols |HTTP, SOAP, DNS, UDP Setup, Telnet, ARP, ICMP, SMTP, SNMP, Modbus |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
 ^RS485 / RS422 / RS232 ^  | ^RS485 / RS422 / RS232 ^  |
-|Interfaces |  2x RS485 or 1x RS422<​sup>​2</​sup> ​ |+|Interfaces |2x RS485 or 1x RS422<​sup>​2</​sup>​ |
 |  |  | |  |  |
-|  |  __//​piggy-back hardware options//__ <​sup>​3</​sup> ​ +|  |__//​piggy-back hardware options//__ <​sup>​3</​sup>​ | 
-|  |  2x RS485 or 1x RS422 opto-isolated<​sup>​2</​sup> ​ +|  |2x RS485 or 1x RS422 opto-isolated<​sup>​2</​sup>​ | 
-|  |  1x RS485 + 1x RS232 | +|  |1x RS485 + 1x RS232 | 
-|  |  1x RS485 + 1x RS232 opto-isolated |+|  |1x RS485 + 1x RS232 opto-isolated |
 |  |  | |  |  |
-|  |  //__SM2-BE extension module__ //  +|  |//__SM2-BE extension module__ // | 
-|  |  1x RS232 + 1x RS485 surge protected<​sup>​4</​sup> ​ |+|  |1x RS232 + 1x RS485 surge protected<​sup>​4</​sup>​ |
 |  |  | |  |  |
-|Speed |  300 .. 115.200 bps (software configurable)<​sup>​2,​ 5</​sup> ​ +|Speed |300 .. 115.200 bps (software configurable)<​sup>​2,​ 5</​sup>​ | 
-|Termination |  Yes, both for half and full duplex, configurable with jumpers |+|Termination |Yes, both for half and full duplex, configurable with jumpers |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
-^Inputs ^  opto-electronically isolated | +^Inputs ^opto-electronically isolated | 
- 3x digital inputs (DI) |  software configurable between dry contact or S0 pulse meter inputs (e.g. from electrometer) | +|3x digital inputs (DI) |software configurable between dry contact or S0 pulse meter inputs (e.g. from electrometer) | 
- Max. distance |  30 m (depends on cable) |+|Max. distance |30 m (depends on cable) |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
 ^Outputs ^  | ^Outputs ^  |
-|1x relay |  32 V, 3 A, protected with power fuse |+|1x relay |32 V, 3 A, protected with power fuse |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
 ^Electrical parameters ^  | ^Electrical parameters ^  |
-|Power supply |  9-35 V DC, typ. 1.2 W @ 12V | +|Power supply |9-35 V DC, typ. 1.2 W @ 12V | 
- DI1, DI2, DI3 |  8-80 V | +|DI1, DI2, DI3 |8-80 V | 
- 1 Wire |  Interface provides 5 V power supply, max. 350 mA, protected with 500 mA power fuse. | +|1 Wire |Interface provides 5 V power supply, max. 350 mA, protected with 500 mA power fuse. | 
- RS485 |  Protected against transient voltages above 6.8V and against high currents with 10Ω resistors. Additional surge protection can be achieved with SM2-BE (bus extension) module with gas discharge tubes: | +|RS485 |Protected against transient voltages above 6.8V and against high currents with 10Ω resistors. Additional surge protection can be achieved with SM2-BE (bus extension) module with gas discharge tubes: | 
-|  |  Minimum DC Sparkover (100 V/s) 185 V | +|  |Minimum DC Sparkover (100 V/s) 185 V | 
-|  |  Service life: | +|  |Service life: | 
-|  |  150 operations 8/20 μs 250 A, 1.2/50, 500 V (IEC61643-21) | +|  |150 operations 8/20 μs 250 A, 1.2/50, 500 V (IEC61643-21) | 
-|  |  20 operations 2/10 μs, 5 kV, 500 A | +|  |20 operations 2/10 μs, 5 kV, 500 A | 
-|  |  2 operations 8/20 μs, 1 kA |+|  |2 operations 8/20 μs, 1 kA |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
 ^Mechanical parameters ^  | ^Mechanical parameters ^  |
-|Dimensions |  71.6 x 89.7 x 62.2 mm | +|Dimensions |71.6 x 89.7 x 62.2 mm | 
-|Mounting |  DIN rail | +|Mounting |DIN rail | 
-|Screw terminals |  05 mm² - 15 mm² cable cores | +|Screw terminals |05 mm² - 15 mm² cable cores 
-|Operating temperature |  0 .. +70 °C | +|Degree of protection |IP20 
-|LED diodes |  Status, RS485, Sensors |+|Operating temperature |0 .. +70 °C | 
 +|LED diodes |Status, RS485, Sensors |
 ^  ^  | ^  ^  |
 |  |  | |  |  |
 ^Extension options |  | ^Extension options |  |
-|Interface |  HBUS (DIN rail, bottom pluggable, no external wires needed) | +|Interface |HBUS (DIN rail, bottom pluggable, no external wires needed) | 
-|Extension modules |  SM2-PC, SM2-AD, SM2-DI, SM2-GSM, SM2-BE |+|Extension modules |[[..:​rozsirujici_moduly:​sm2_pc|SM2-PC]][[..:​rozsirujici_moduly:​sm2_ad|SM2-AD]][[..:​rozsirujici_moduly:​sm2_di|SM2-DI]][[..:​rozsirujici_moduly:​sm2_gsm|SM2-GSM]][[..:​rozsirujici_moduly:​sm2_be|SM2-BE]] |
  
  
Line 90: Line 86:
 \\  \\ 
 <​sup>​5 … Communication speeds are available according to selected device communication protocols. </​sup> ​ <​sup>​5 … Communication speeds are available according to selected device communication protocols. </​sup> ​
- 
- 
 \\ \\
 +{{  :​en:​sim:​manual:​popis:​sm2_vykres.png?​nolink& ​ }}
  
en/sim/manual/popis/parametry_zakladniho_modulu.1476774671.txt.gz · Last modified: 2016/10/18 09:11 by ondra