This shows you the differences between two versions of the page.
en:sim:rm:web_zarizeni:vstupy_a_mereni [2014/08/28 14:42] jitka |
en:sim:rm:web_zarizeni:vstupy_a_mereni [2014/09/11 10:16] (current) ondra |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | ===== Inputs and Measurement ===== | + | ===== Inputs & Meters ===== |
Line 5: | Line 5: | ||
- | In SM2-RM go to menu System Setup/Inputs and Measurement.\\ | + | In SM2-RM go to menu System Setup/Inputs & Meters.\\ |
- | \\ | + | |
- | {{ :en:sim:rm:web_zarizeni:vstupy_a_mereni_3citace.png?nolink& }}\\ | + | |
- | \\ | + | |
\\ | \\ | ||
+ | {{ .:vstupy_a_mereni_3citace.png?nolink& }}\\ | ||
==== Input 1, Input 2, Input 3 ==== | ==== Input 1, Input 2, Input 3 ==== | ||
Line 16: | Line 14: | ||
Assign each input its function.\\ | Assign each input its function.\\ | ||
\\ | \\ | ||
- | If you assign input **Reading ** function, it will read pulses.\\ | + | If you assign input **Counter ** function, it will count pulses.\\ |
- | <WRAP info> You can erase pulse score by changing energy correction, by changing input function (Reader, Inactive) or by pressing a reset button for 4 sec. The reset button is at the top of the box bellow Status diode. You can use e.g. a paper clip to press the button. </WRAP> If you choose **Input** function, there will be value 1 or 2 (connected, disconnected) in "Overview".\\ | + | <WRAP info> You can erase pulse score by changing energy correction, by changing input function (Reader, Inactive) or by pressing a reset button for 4 sec. The reset button is at the top of the box bellow Status diode. You can use e.g. a paper clip to press the button. </WRAP> If you choose **Input** function, there will be value 1 or 2 (connected, disconnected) in "Overview".\\ |
\\ | \\ | ||
In case there is no device connected, choose **Inactive**.\\ | In case there is no device connected, choose **Inactive**.\\ | ||
\\ | \\ | ||
**Name** \\ | **Name** \\ | ||
- | You can assign the input any name (e.g. electrometer, gas meter, door sensor...).\\ | + | You can assign the input any name (e.g. electrometer, gas meter, door sensor…).\\ |
\\ | \\ | ||
**Meter Type** \\ | **Meter Type** \\ | ||
Line 30: | Line 28: | ||
\\ | \\ | ||
**Number of Pulses per 1 (kWh, m³)** \\ | **Number of Pulses per 1 (kWh, m³)** \\ | ||
- | Fill in the number of pulses per a unit (kWh, m³), that your meter generates at the SO output. This information is stated at the meter's label or in its documentation. If wrong number of pulses is entered, SM2-RM will show wrong production or consumption values.\\ | + | Fill in the number of pulses per a unit (kWh, m³), that your meter generates at the SO output. This information is stated at the meter's label or in its documentation. If wrong number of pulses is entered, SM2-RM will show wrong production or consumption values.\\ |
\\ | \\ | ||
It is essential that electro meter's pulse output is configured for delivery.\\ | It is essential that electro meter's pulse output is configured for delivery.\\ | ||
Line 36: | Line 34: | ||
<WRAP info> Default setting is reading pulses from the electro meter, value 1000 pulses per 1 kWh. If your electro meter shows a different number, change the setting. </WRAP> <WRAP half column>\\ | <WRAP info> Default setting is reading pulses from the electro meter, value 1000 pulses per 1 kWh. If your electro meter shows a different number, change the setting. </WRAP> <WRAP half column>\\ | ||
The number of impulses per 1 kWh is usually between 250-1000 imp/1kWh. In case there are 2 possible numbers of impulses at your electro meter, the lower number is usually the right one for the SO output.\\ | The number of impulses per 1 kWh is usually between 250-1000 imp/1kWh. In case there are 2 possible numbers of impulses at your electro meter, the lower number is usually the right one for the SO output.\\ | ||
- | The higher number tells you how often a LED diode at your electro meter switches on. </WRAP> <WRAP half column> {{ :en:sim:rm:rychly_navod:jak_na_to:obrazek_elmeru.png?100 }}</WRAP>\\ | + | The higher number tells you how often a LED diode at your electro meter switches on. </WRAP> <WRAP half column> {{ ..:rychly_navod:jak_na_to:obrazek_elmeru.png?100 }}</WRAP>\\ |
**In case you need to setup number of pulses other than 1000 per 1 kWh než 1000, it is essential to differentiate between direct and indirect measurement:** | **In case you need to setup number of pulses other than 1000 per 1 kWh než 1000, it is essential to differentiate between direct and indirect measurement:** | ||
==== 1. Direct Measuring ==== | ==== 1. Direct Measuring ==== | ||
- | In the electro meter's label or documentation find out how many pulses per 1 kWh your electro meter generates at the SO output. Fill in this value into relevant box in SM2-RM menu.\\ | + | In the electro meter's label or documentation find out how many pulses per 1 kWh your electro meter generates at the SO output. Fill in this value into relevant box in SM2-RM menu. |
+ | |||
==== 2. Indirect Measuring ==== | ==== 2. Indirect Measuring ==== | ||
Line 52: | Line 52: | ||
\\ | \\ | ||
</WRAP> <WRAP half column>\\ | </WRAP> <WRAP half column>\\ | ||
- | {{ :en:sim:rm:rychly_navod:jak_na_to:pocet_pulzu_pomer.png?200 }}\\ | + | {{ ..:rychly_navod:jak_na_to:pocet_pulzu_pomer.png?200 }}\\ |
\\ | \\ | ||
\\ | \\ | ||
Line 59: | Line 59: | ||
- | **Meter's Correction ** \\ | + | **Meter Correction ** \\ |
This box is used for initial setting up SM2-RM and pulse meter. Fill in current value of kWh or m³ that your meter displays.\\ | This box is used for initial setting up SM2-RM and pulse meter. Fill in current value of kWh or m³ that your meter displays.\\ | ||
\\ | \\ | ||
Line 67: | Line 67: | ||
\\ | \\ | ||
//Example of another input function:// \\ | //Example of another input function:// \\ | ||
- | {{ :en:sim:rm:web_zarizeni:vstupy_a_mereni_vice_moznosti.png?nolink& }} | + | {{ .:vstupy_a_mereni_vice_moznosti.png?nolink& }} |