User Tools

Site Tools


en:sim:rm:web_zarizeni:vstupy_a_mereni

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

en:sim:rm:web_zarizeni:vstupy_a_mereni [2014/09/02 08:22]
jitka
en:sim:rm:web_zarizeni:vstupy_a_mereni [2014/09/11 10:16] (current)
ondra
Line 1: Line 1:
-===== Inputs ​and Measurement ​=====+===== Inputs ​& Meters ​=====
  
  
Line 5: Line 5:
  
  
-In SM2-RM go to menu System Setup/​Inputs ​and Measurement.\\ +In SM2-RM go to menu System Setup/​Inputs ​& Meters.\\ 
 \\  \\ 
-{{  ​:​en:​sim:​rm:​web_zarizeni:​vstupy_a_mereni_3citace.png?​nolink& ​ }}\\ +{{  ​.:​vstupy_a_mereni_3citace.png?​nolink& ​ }}\\ 
 ==== Input 1, Input 2, Input 3 ==== ==== Input 1, Input 2, Input 3 ====
  
Line 34: Line 34:
 <WRAP info> Default setting is reading pulses from the electro meter, value 1000 pulses per 1 kWh. If your electro meter shows a different number, change the setting. </​WRAP>​ <WRAP half column>​\\ ​ <WRAP info> Default setting is reading pulses from the electro meter, value 1000 pulses per 1 kWh. If your electro meter shows a different number, change the setting. </​WRAP>​ <WRAP half column>​\\ ​
 The number of impulses per 1 kWh is usually between 250-1000 imp/1kWh. In case there are 2 possible numbers of impulses at your electro meter, the lower number is usually the right one for the SO output.\\ ​ The number of impulses per 1 kWh is usually between 250-1000 imp/1kWh. In case there are 2 possible numbers of impulses at your electro meter, the lower number is usually the right one for the SO output.\\ ​
-The higher number tells you how often a LED diode at your electro meter switches on. </​WRAP>​ <WRAP half column> {{  ​:en:sim:rm:​rychly_navod:​jak_na_to:​obrazek_elmeru.png?​100 ​ }}</​WRAP>​\\ ​+The higher number tells you how often a LED diode at your electro meter switches on. </​WRAP>​ <WRAP half column> {{  ​..:​rychly_navod:​jak_na_to:​obrazek_elmeru.png?​100 ​ }}</​WRAP>​\\ ​
 **In case you need to setup number of pulses other than 1000 per 1 kWh než 1000, it is essential to differentiate between direct and indirect measurement:​** ​ **In case you need to setup number of pulses other than 1000 per 1 kWh než 1000, it is essential to differentiate between direct and indirect measurement:​** ​
 ==== 1. Direct Measuring ==== ==== 1. Direct Measuring ====
Line 52: Line 52:
 \\  \\ 
 </​WRAP>​ <WRAP half column>​\\ ​ </​WRAP>​ <WRAP half column>​\\ ​
-{{  ​:en:sim:rm:​rychly_navod:​jak_na_to:​pocet_pulzu_pomer.png?​200 ​ }}\\ +{{  ​..:​rychly_navod:​jak_na_to:​pocet_pulzu_pomer.png?​200 ​ }}\\ 
 \\  \\ 
 \\  \\ 
Line 67: Line 67:
 \\  \\ 
 //Example of another input function:// \\  //Example of another input function:// \\ 
-{{  ​:​en:​sim:​rm:​web_zarizeni:​vstupy_a_mereni_vice_moznosti.png?​nolink& ​ }}+{{  ​.:​vstupy_a_mereni_vice_moznosti.png?​nolink& ​ }}
  
en/sim/rm/web_zarizeni/vstupy_a_mereni.1409638955.txt.gz · Last modified: 2014/09/02 08:22 by jitka