Reading Inverters via Ethernet






To be set up in the submenu Inverters & Meters


Type of protocol



Select the manufacturer of your inverter.



Setting up network interface has two address modes:
1. IP Address
2. Port


IP Address Detection of Inverters

Use this type of detection for inverters with different IP addresses.

Address the inverters first. Assign consequent IP addresses to the inverters and the port number. The port number is the same for all inverters. Further info on how to address the inverters to be found in inverter's documentation.



IP Address
Enter inverter with the lowest IP address in the network. Detection starts with this address and searches for following higher IP addresses until the required number of destinations has been searched.

Port
Enter port's number.

Addressing Mode
Select addressing mode depending on the IP address.

The number of destinations
The number of IP addresses of all devices.

Detected devices
The number of devices assigned to each destination.

Read Connected Inverters
Click on buttonto detect inverters connected to SM2-MU

Detection can take up to several minutes depending on the type of protocol and the number of inverters.

To be detected, inverters must be on, i.e. they must have sufficient electric current coming from the PV panels.

When detection is finished, the list of connected inverters is displayed.






Save changes you have made.



For detailed info on inverter's production, click on a particular inverter in the menu Production Overview.

Port Detection of Inverters

Use this type of detection for inverters with the same IP address that are located at different ports.

Address the inverters first. Assign one IP address for all inverters. Assign consequent numbers of ports to inverters. Addressing procedure to be found in inverter's documentation.



IP address
Enter IP address, the same address for all inverters.

Port
Enter inverter with the lowest port number (destination) at a particular IP address. Detection starts with this port and searches for following higher port numbers until the required number of destinations has been searched.

Addressing mode
Select addressing mode according to the port.

The Number of Destinations
The number of ports where the devices have been addressed.

Detected devices
The number of devices assigned to each destination.


Read connected inverters
Click on buttonto detect inverters connected to SM2-MU.

Detection can take up to several minutes depending on the type of protocol and the number of inverters.

To be detected, inverters must be on, i.e. they must have sufficient electric current coming from the PV panels.

When detection is finished, the list of connected inverters is displayed.






Save the changes you have made .



For detailed info on inverter's production, click on a particular inverter in the menu Production Overview.