Production overview


Production overview gives you overall information about your PV plant.


This menu shows all important information about your PV plant. If there is an alarm status of any component (it doesn't work properly or exceeds limit values) it is highlighted in colours.


Yellow colour appears immediately after exceeding the limits. With sensors that send notification (e-mail, SMS) or record alarms in history, this status is considered an alarm after the “sensor alarm delay” runs out. Red colour appears, notification to the user is sent and/or it is recorded in alarm history.

Relevant sensor setup, time delays before alarm announcement and ways of notification to the user to be found in chapter Sensors and alarms.

Power production, Outputs

These boxes show today's and total production in kWh and today's and total revenue in Czech crowns. Revenue is calculated roughly: multiply number of kWh produced by current Green Bonus price (or obligatory purchase). You have to set up the prices in menu Billing/Price setting, see chapter Price setting.

Information from inverters

All connected and correctly set up inverters are shown here, including their status, current regime, output and temperature. These values come straight from the inverters every second.

Some manufacturers don't give all parameters (e.g. temperature).

Sensor values

This box shows all detected sensors and their current values. The values are updated every second. You can name sensors and set up limit values in menu System setting/Sensors and alarms, see chapter Sensors and alarms.

Input and output values

It shows current status of two relay-inputs in Solar Monitor unit. Each input has two possible states: Connected or Disconnected. You can use these inputs to connect any component with contact status signaling - e.g. surge, movement sensor, door sensor, optical barrier or security output.

Inputs are able to distinguish 100 millisecond.

You will find Description of input connection and their set up in chapter Digital inputs and outputs.

With output module connected and permitted, it shows current status of two-relay output as well.